Menu

Javascript is not activated in your browser. This website needs javascript activated to work properly.
You are here

Single tumor cell uptake and dosimetry of technetium-99m Fab ' anti-CD22 in low-grade B-cell lymphoma

Author:
  • Ola Lindén
  • Cecilia Hindorf
  • Jan Tennvall
  • Sverker Segren
  • Karin Wingårdh
  • Sven-Erik Strand
Publishing year: 2002
Language: English
Pages: 1270-1274
Publication/Series: Cancer
Volume: 94
Issue: 4
Document type: Journal article
Publisher: John Wiley & Sons

Abstract english

BACKGROUND. A patient with follicular lymphoma was investigated with 0.5 mg Fab' anti-CD22 labeled with 1100 MBq technetium-99m (Tc-99m). A computed tomography scan performed a week later revealed regression. This unexpected response prompted an investigation of single cell dosimetry of low-energy electron emitters. METHODS. Another patient with low-grade, unclassifiable B-cell lymphoma with a low expression of CD22 was injected with Tc-99m anti-CD22. Blood samples were drawn 30 minutes, 4 hours, and 24 hours after injection. Lymphoma cells (CD19+) and T cells (CD3+), which served as control cells, were separated using a flow cytometer. The radioactivity of the two cell Populations was Measured in an NaI(Tl) well-type detector. The mean uptake per cell and absorbed dose were calculated. The CD22 expression of the patient's cells and of a B-cell lymphoma cell line (Raji) were assessed by flow cytometry for die extrapolation of the absorbed dose from the patient's cells to a cell line with higher CD22 expression. RESULTS. The average number of Tc-99m atoms per CD19+ and CD3 cell 4 hours postinjection were 5.4 and 0.054, respectively. Depending on the assumed ratio between antibody and CD22 molecules (1:2 or 1:1), the CD22 expression on the patient's cells and Raji cells varied from 2800 to 5700 and from 37,000 to 74,000 per cell, respectively. The average absorbed dose per cell ranged from 4 x 10(-7) to 0.1 grays (Gy). CONCLUSIONS. It seems feasible to assess the mean single tumor cell uptake of Tc-99m targeted by Fab' anti-CD22 in a patient's lymphoma using sorted cell populations, thereby allowing single cell dosimetry. Extrapolation of the absorbed dose from Tc-99m to cells with higher CD22 expression was made and under certain conditions absorbed doses of 0.1 Gy were obtained, indicating the potential relevance of low-energy elCancer 2002;94:1270-4.

Keywords

  • Cancer and Oncology
  • radioimmunotherapy
  • single cell
  • dosimetry
  • technetium-99m

Other

Published
  • ISSN: 1097-0142
Sven-Erik Strand
E-mail: sven-erik [dot] strand [at] med [dot] lu [dot] se

Project manager

Systemic Radiation Therapy Group

32

Professor emeritus

Medical Radiation Physics, Lund

32