Menu

Javascript is not activated in your browser. This website needs javascript activated to work properly.
You are here

Perfusion quantification by model-free arterial spin labeling using nonlinear stochastic regularization deconvolution.

Author:
  • André Ahlgren
  • Ronnie Wirestam
  • Esben Thade Petersen
  • Freddy Ståhlberg
  • Linda Knutsson
Publishing year: 2013
Language: English
Pages: 1470-1480
Publication/Series: Magnetic Resonance in Medicine
Volume: 70
Issue: 5
Document type: Journal article
Publisher: Wiley Online Library

Abstract english

Purpose: Quantification of cerebral blood flow can be accomplished by model-free arterial spin labeling using the quantitative STAR labeling of arterial regions (QUASAR) sequence. The required deconvolution is normally based on block-circulant singular value decomposition (cSVD)/oscillation SVD (oSVD), an algorithm associated with nonphysiological residue functions and potential effects of arterial dispersion. The aim of this work was to amend this by implementing nonlinear stochastic regularization (NSR) deconvolution, previously used to retrieve realistic residue functions in dynamic susceptibility contrast MRI. METHODS: To characterize the residue function in model-free arterial spin labeling, and possibly to improve absolute cerebral blood flow quantification, NSR was applied to deconvolution of QUASAR data. For comparison, SVD-based deconvolution was also employed. Residue function characteristics and cerebral blood flow values from 10 volunteers were obtained. Simulations were performed to support the in vivo results. RESULTS: NSR was able to resolve realistic residue functions in contrast to the SVD-based methods. Mean cerebral blood flow estimates in gray matter were 36.6 ± 2.6, 28.6 ± 3.3, 40.9 ± 3.6, and 42.9 ± 3.9 mL/100 g/min for cSVD, oSVD, NSR, and NSR with correction for arterial dispersion, respectively. In simulations, the NSR-based perfusion estimates showed better accuracy than the SVD-based approaches. CONCLUSION: Perfusion quantification by model-free arterial spin labeling is evidently dependent on the selected deconvolution method, and NSR is a feasible alternative to SVD-based methods. Magn Reson Med, 2012. © 2012 Wiley Periodicals, Inc.

Keywords

  • Radiology, Nuclear Medicine and Medical Imaging

Other

Published
  • ISSN: 1522-2594
Freddy Ståhlberg
E-mail: freddy [dot] stahlberg [at] med [dot] lu [dot] se

Professor

Medical Radiation Physics, Lund

+46 46 17 31 19

+46 70 688 31 19

32

Professor

Diagnostic Radiology, (Lund)

+46 46 17 70 30

32

Project manager

MR Physics

32